home
layout
rack
Show All Chassis
Show Documents
Show Chassis Types and locations
login
Edsac Replica Project - Chassis Details
Bench-5 CCU Panel XI
Bench-9 Digit Pulse Distributor Unit
Bench-12 Maintenance Panel
F1-2 Store Regeneration Unit
F1-3 Store Regeneration Unit
F1-4 Store Regeneration Unit
F1-5 Store Regeneration Unit
F1-6 Final Tank Decoder
F1-7 Tank Decoder Logic
F1-8 Tank Decoder Distributor
F1-9 Final Tank Decoder
F1-10 Store Regeneration Unit
F1-11 Store Regeneration Unit
F1-12 Store Regeneration Unit
F1-13 Store Regeneration Unit
F2-2 Store Regeneration Unit
F2-3 Store Regeneration Unit
F2-4 Store Regeneration Unit
F2-5 Store Regeneration Unit
F2-6 Final Tank Decoder
F2-7 Tank Decoder Logic
F2-8 Tank Decoder Distributor
F2-9 Final Tank Decoder
F2-10 Store Regeneration Unit
F2-11 Store Regeneration Unit
F2-12 Store Regeneration Unit
F2-13 Store Regeneration Unit
F3-1 Negative PSU
F3-2 Digit Pulse Generator Type 1
F3-3 Digit Pulse Generator Type 1
F3-4 Digit Pulse Generator Type 1
F3-5 Digit Pulse Generator Type 1
F3-6 Digit Pulse Generator Type 1
F3-7 Digit Pulse Generator Type 2
F3-8 Digit Pulse Generator Type 2
F3-9 Digit Pulse Distributor (DU2)
F3-10 Clock Pulse Distributor (DU1)
F3-12 Clock Pulse Generator
F3-13 Clock Monitor
F4-4 Printer Unit 3
F4-5 Printer Unit 2
F4-6 Printer Unit 1
F4-7 Paper Tape Unit 2
F4-8 Paper Tape Unit 1
F4-9 Manual Order Unit
F4-10 Initial Input Unit 2
F4-11 Initial Input Unit 1
F4-13 Initial Orders Uniselectors
M1-1 Power Supply Unit
M1-2 Main Control Unit 2 M-2
M1-3 Main Control Unit 3 M-3
M1-4 Main Control Unit 1 M-1
M1-5 Coincidence Unit 2
M1-6 Coincidence Unit 1
M1-7 Counter + SCT Control
M1-8 Order Tank Control
M1-9 SCT Half Adder
M1-10 Counter Half Adder
M1-11 Order Tank Regen
M1-12 Coincidence Unit 3
M1-13 Sequence Control Tank Regen
M1-14 Counter Tank Regen
M2-1 Power Supply Unit
M2-2 Order Secondary Decoder Type 1 C-4
M2-3 Order Secondary Decoder Type 1 C-3
M2-4 Order Distributer Unit D-2
M2-5 Order Secondary Decoder Type 2 C-2
M2-6 Order Secondary Decoder Type 1 C-1
M2-7 Order Distributer Unit D-1
M2-8 Order Coder Unit Type 2 E-2
M2-9 Order Coder Unit Type 1 E-1
M2-10 Operator's Control Unit
M2-11 Transfer Unit 2
M2-12 Transfer Unit 1
M2-13 Transfer Tank Regen
M3-1 Power Supply Unit
M3-2 Order Flashing Unit Type 2 A-3
M3-3 Order Flashing Unit Type 2 A-2
M3-4 Order Flashing Unit Type 1 A-1
M3-5 Order Primary Decoder B-1
M3-8 Flashing Unit Type 2
M3-9 Flashing Unit Type 2
M3-10 Flashing Unit Type 2
M3-11 Flashing Unit Common
M3-12 Rack Distribution Logic
M3-13 Rack Decoder
Power-0 Internal HT Soft Start
Power-0 Power Rack
Power-1 HT PSU 3
Power-2 HT PSU 2
Power-3 HT PSU 1
Power-4 AC Protection
Power-5 DC+HT Protection
Power-6 AC Metering
Power-7 HT Metering
Power-8 DC Metering
Power-9 Spare
Power-10 Control Panel
R1-2 Store Regeneration Unit
R1-3 Store Regeneration Unit
R1-4 Store Regeneration Unit
R1-5 Store Regeneration Unit
R1-6 Final Tank Decoder
R1-7 Tank Decoder Logic
R1-8 Tank Decoder Distributor
R1-9 Final Tank Decoder
R1-10 Store Regeneration Unit
R1-11 Store Regeneration Unit
R1-12 Store Regeneration Unit
R1-13 Store Regeneration Unit
R2-2 Store Regeneration Unit
R2-3 Store Regeneration Unit
R2-4 Store Regeneration Unit
R2-5 Store Regeneration Unit
R2-6 Final Tank Decoder
R2-7 Tank Decoder Logic
R2-8 Tank Decoder Distributor
R2-9 Final Tank Decoder
R2-10 Store Regeneration Unit
R2-11 Store Regeneration Unit
R2-12 Store Regeneration Unit
R2-13 Store Regeneration Unit
R3-2 ASU 2
R3-3 ASU 1
R3-4 Accumulator Tank 1 Regen
R3-5 Accumulator Tank 2 Regen
R3-6 Half Adder 1
R3-7 Half Adder 2
R3-8 Distributing Unit 3
R3-9 Collater Unit
R3-10 Complementer Unit
R3-11 Partial Product Adder
R3-12 CCU VI
R3-13 CCU X
R4-2 CCU II Mult Control
R4-3 CCU III Shifting Control
R4-4 Accumulator supportUnit
R4-5 CCU V Rounding
R4-6 TCT Shifting Control
R4-7 TCT Regen
R4-8 Multiplicand Control Unit
R4-10 Multiplicand Tank Regen
R4-11 Multiplicand Shifting Unit
R4-12 Multiplier Tank Regen
R4-13 Multiplier Support Unit
R5-6 CCU VII
R5-7 CCU IV Arithmetic Control
R5-8 CCU IX & XI Register Clear
R5-9 CCU I
R5-11 CCU VIII
R5-13 Buffers
Chassis F3:8: Digit Pulse Generator Type 2
Title:
Digit Pulse Generator Type 2
Location
Rack:
F3
Shelf:
8
Chassis type
:
15 Ser: 02
Current Owner:
JS
Status:
In Rack
Name
Pos
I/O
Vmax
Vmin
Wires?
CLK
2
I
-
-
->
F3:12:8(O)
->
F3:7:2(I)
->
F3:6:2(I)
->
F3:5:2(I)
->
F3:4:2(I)
->
F3:3:2(I)
->
F3:2:2(I)
Gate In
6
I
-
-
->
F3:7:28(O)
Digit 1
10
O
-
-
->
F3:9:55(I)
Digit 2
16
O
-
-
->
F3:10:36(I)
Digit 3
20
O
-
-
Digit 4
24
O
-
-
Gate Out
28
O
-
-
-6V
32
I
-
-
->
F3:7:32(I)
->
F3:6:32(I)
->
F3:5:32(I)
->
F3:4:32(I)
->
F3:3:32(I)
->
F3:2:32(I)
->
F3:1:32(O)
•
Images of the the chassis
None available
•
Chassis drawings
EDSAC_Shelf_03.dxf
EDSAC_Shelf_03.pdf
•
Link to circuit diagram
Digit_Pulse_Generator_Type_2_Schematic.pdf
Digit_Pulse_Generator_Type_2_Schematic.sch
•
Link to logic diagram
None available
•
Hardware Notes
None available
•
Other related documents
None available
Bench-5 CCU Panel XI
Bench-9 Digit Pulse Distributor Unit
Bench-12 Maintenance Panel
F1-2 Store Regeneration Unit
F1-3 Store Regeneration Unit
F1-4 Store Regeneration Unit
F1-5 Store Regeneration Unit
F1-6 Final Tank Decoder
F1-7 Tank Decoder Logic
F1-8 Tank Decoder Distributor
F1-9 Final Tank Decoder
F1-10 Store Regeneration Unit
F1-11 Store Regeneration Unit
F1-12 Store Regeneration Unit
F1-13 Store Regeneration Unit
F2-2 Store Regeneration Unit
F2-3 Store Regeneration Unit
F2-4 Store Regeneration Unit
F2-5 Store Regeneration Unit
F2-6 Final Tank Decoder
F2-7 Tank Decoder Logic
F2-8 Tank Decoder Distributor
F2-9 Final Tank Decoder
F2-10 Store Regeneration Unit
F2-11 Store Regeneration Unit
F2-12 Store Regeneration Unit
F2-13 Store Regeneration Unit
F3-1 Negative PSU
F3-2 Digit Pulse Generator Type 1
F3-3 Digit Pulse Generator Type 1
F3-4 Digit Pulse Generator Type 1
F3-5 Digit Pulse Generator Type 1
F3-6 Digit Pulse Generator Type 1
F3-7 Digit Pulse Generator Type 2
F3-8 Digit Pulse Generator Type 2
F3-9 Digit Pulse Distributor (DU2)
F3-10 Clock Pulse Distributor (DU1)
F3-12 Clock Pulse Generator
F3-13 Clock Monitor
F4-4 Printer Unit 3
F4-5 Printer Unit 2
F4-6 Printer Unit 1
F4-7 Paper Tape Unit 2
F4-8 Paper Tape Unit 1
F4-9 Manual Order Unit
F4-10 Initial Input Unit 2
F4-11 Initial Input Unit 1
F4-13 Initial Orders Uniselectors
M1-1 Power Supply Unit
M1-2 Main Control Unit 2 M-2
M1-3 Main Control Unit 3 M-3
M1-4 Main Control Unit 1 M-1
M1-5 Coincidence Unit 2
M1-6 Coincidence Unit 1
M1-7 Counter + SCT Control
M1-8 Order Tank Control
M1-9 SCT Half Adder
M1-10 Counter Half Adder
M1-11 Order Tank Regen
M1-12 Coincidence Unit 3
M1-13 Sequence Control Tank Regen
M1-14 Counter Tank Regen
M2-1 Power Supply Unit
M2-2 Order Secondary Decoder Type 1 C-4
M2-3 Order Secondary Decoder Type 1 C-3
M2-4 Order Distributer Unit D-2
M2-5 Order Secondary Decoder Type 2 C-2
M2-6 Order Secondary Decoder Type 1 C-1
M2-7 Order Distributer Unit D-1
M2-8 Order Coder Unit Type 2 E-2
M2-9 Order Coder Unit Type 1 E-1
M2-10 Operator's Control Unit
M2-11 Transfer Unit 2
M2-12 Transfer Unit 1
M2-13 Transfer Tank Regen
M3-1 Power Supply Unit
M3-2 Order Flashing Unit Type 2 A-3
M3-3 Order Flashing Unit Type 2 A-2
M3-4 Order Flashing Unit Type 1 A-1
M3-5 Order Primary Decoder B-1
M3-8 Flashing Unit Type 2
M3-9 Flashing Unit Type 2
M3-10 Flashing Unit Type 2
M3-11 Flashing Unit Common
M3-12 Rack Distribution Logic
M3-13 Rack Decoder
Power-0 Internal HT Soft Start
Power-0 Power Rack
Power-1 HT PSU 3
Power-2 HT PSU 2
Power-3 HT PSU 1
Power-4 AC Protection
Power-5 DC+HT Protection
Power-6 AC Metering
Power-7 HT Metering
Power-8 DC Metering
Power-9 Spare
Power-10 Control Panel
R1-2 Store Regeneration Unit
R1-3 Store Regeneration Unit
R1-4 Store Regeneration Unit
R1-5 Store Regeneration Unit
R1-6 Final Tank Decoder
R1-7 Tank Decoder Logic
R1-8 Tank Decoder Distributor
R1-9 Final Tank Decoder
R1-10 Store Regeneration Unit
R1-11 Store Regeneration Unit
R1-12 Store Regeneration Unit
R1-13 Store Regeneration Unit
R2-2 Store Regeneration Unit
R2-3 Store Regeneration Unit
R2-4 Store Regeneration Unit
R2-5 Store Regeneration Unit
R2-6 Final Tank Decoder
R2-7 Tank Decoder Logic
R2-8 Tank Decoder Distributor
R2-9 Final Tank Decoder
R2-10 Store Regeneration Unit
R2-11 Store Regeneration Unit
R2-12 Store Regeneration Unit
R2-13 Store Regeneration Unit
R3-2 ASU 2
R3-3 ASU 1
R3-4 Accumulator Tank 1 Regen
R3-5 Accumulator Tank 2 Regen
R3-6 Half Adder 1
R3-7 Half Adder 2
R3-8 Distributing Unit 3
R3-9 Collater Unit
R3-10 Complementer Unit
R3-11 Partial Product Adder
R3-12 CCU VI
R3-13 CCU X
R4-2 CCU II Mult Control
R4-3 CCU III Shifting Control
R4-4 Accumulator supportUnit
R4-5 CCU V Rounding
R4-6 TCT Shifting Control
R4-7 TCT Regen
R4-8 Multiplicand Control Unit
R4-10 Multiplicand Tank Regen
R4-11 Multiplicand Shifting Unit
R4-12 Multiplier Tank Regen
R4-13 Multiplier Support Unit
R5-6 CCU VII
R5-7 CCU IV Arithmetic Control
R5-8 CCU IX & XI Register Clear
R5-9 CCU I
R5-11 CCU VIII
R5-13 Buffers
Page maintained by Bill Purvis
Last updated 2020-12-05
data last updated: 2021-01-30